Adams Rite PS-EXIT Power Supply for 8000 and 3000 Series MLR or LR Exit Devices

PS-EXIT

|

R8-PSEXIT

Se connecter prix revendeur

Vous n’êtes pas encore client d’ADI?Devenir Client
Adams Rite PS-EXIT Ps-Exit Power Supply
Acheter Adams Rite by ASSA ABLOY

Adams Rite PS-EXIT Power Supply for 8000 and 3000 Series MLR or LR Exit Devices

PS-EXIT | R8-PSEXIT

Veuillez vous connecter pour voir les tarifs, consulter la disponibilité des produits et ajouter des articles à votre panier.

Aperçu
Spécifications
Documents

Aperçu

The PS-EXIT Power Supply is specifically designed to protect and optimize the performance of Adams Rite 8000/3000 Series exit devices with Motorized Latch Retraction (MLR) or Electric Latch Retraction (LR) options by delivering filtered and regulated power.

Function:

This power supply is designed to provide power and control for up to two MLR or LR exit devices. Each exit device is controlled by a timer that is initiated by a switch closure. The timer is user-configured and holds the exit device(s) in the unlatched position for 2 - 60 seconds. At the end of the selected time, the exit device(s) will re-latch. If the switch controlling the exit device is closed longer than the selected time, the exit device remains unlatched until the controlling switch is released.

  • An optional mode is available that allows both retraction timers to activate in response to a closure of either switch.
  • Exit devices under access system control remain latched during a complete power failure but always allow free mechanical egress

Features:

Housing: Hinged, steel cabinet measures 10" x10-3/8" x 4-1/8" [254 mm x 263.5 mm x104.8 mm]. Blue, baked enamel finish with knockouts for conduit connections. Sized to accommodate two sealed, lead acid batteries (7AH, not included).

Timer: Initiated by switch closure to control each exit device. Timer is user-configured and holds exit device in unlatched position for 2 - 60 seconds. At end of selected time, exit device will relatch.

Operating Modes: The PS-EXIT is designed to power up to two 8000/3000 MLR or LR exit devices in the following operating modes:

  • Single Input (Sequential Operation): either input retracts the corresponding exit device followed by retraction of second device. Control double-door exit with one input.
  • Dual Input (Independent Operation): Each exit device is controlled by its own input switch. Control two separate exits with two inputs.