adi-insite-ca
ADI a Resideo company
menu
Image of AX-MAXIM3DV

Altronix MAXIMAL33FDV Access Power Controller with Power Supply / Chargers, 16 PTC Class 2 Relay Outputs, Dual 12/24VDC P/S at 6A Each, FAI, LinQ2 Ready, 220VAC, BC800 Enclosure

MAXIMAL33FDV|AX-MAXIM3DV

Altronix MAXIMAL33FDV Access Power Controller with Power Supply / Chargers, 16 PTC Class 2 Relay Outputs, Dual 12/24VDC P/S at 6A Each, FAI, LinQ2 Ready, 220VAC, BC800 Enclosure

MAXIMAL33FDV|AX-MAXIM3DV

Se connecter prix revendeur

Devenir client ADI
Altronix

Altronix MAXIMAL33FDV Access Power Controller with Power Supply / Chargers, 16 PTC Class 2 Relay Outputs, Dual 12/24VDC P/S at 6A Each, FAI, LinQ2 Ready, 220VAC, BC800 Enclosure

MAXIMAL33FDV | AX-MAXIM3DV

Veuillez vous connecter pour voir les tarifs, consulter la disponibilité des produits et ajouter des articles à votre panier.

Aperçu
Spécifications
Documents

Aperçu

Introducing the Altronix MAXIMAL33FDV Access Power Controller, designed to efficiently manage and distribute power to your access control systems and accessories. This robust unit transforms a 220V AC input into sixteen independently controlled 12V DC or 24V DC outputs, all protected by PTC. It seamlessly integrates with various access control devices, including mag locks and electric strikes, and supports both fail-safe and fail-secure modes. With features like emergency egress and alarm monitoring, this controller is essential for any security setup. Upgrade your access control system today with the Altronix MAXIMAL33FDV and experience reliable power management!

Principales caractéristiques

  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the sixteen (16) outputs
  • Normally open (NO) or normally closed (NC) dry contact input
  • Polarity reversal input from FACP signaling circuit
  • Alarm output relay indicates that FACP input is triggered (form "C" contact rated at 1A 28V DC)
  • AC fail supervision (form "C" contacts)
  • Notification trigger is selectable for 30 seconds (factory set) or 2 hours
  • Low battery and battery presence supervision (form "C" contact)
  • Capacity: 12AH/12V DC (4 within enclosure); 40AH/65AH (requires separate enclosure)
  • Type Sealed lead acid or gel type
  • Failover: Upon AC loss, instantaneous
  • Renseignements généraux

    Nom:Altronix MAXIMAL33FDV Access Power Controller with Power Supply / Chargers, 16 PTC Class 2 Relay Outputs, Dual 12/24VDC P/S at 6A Each, FAI, LinQ2 Ready, 220VAC, BC800 Enclosure
    Category:Altronix, Batteries & Power Supplies, Power Supplies & Boards, Access Power Controllers
    UPC Code:
    Country of Origin:. Country of origin is subject to change.

    Spécifications

    Documents et ressources sur les produits