Altronix
Altronix EFLOW6NA8V Power Supply with ACM8
EFLOW6NA8V | AX-EFLOW68V
Veuillez vous connecter pour voir les tarifs, consulter la disponibilité des produits et ajouter des articles à votre panier.
Aperçu
Spécifications
Documents
Aperçu
Introducing the Altronix EFLOW6NA8V, a versatile power supply designed to efficiently distribute and manage power for access control systems and accessories. This unit transforms a 220V AC input into eight independently controlled outputs, offering both 12V DC and 24V DC options, with a robust 6A continuous supply current. Each output is fuse protected and can be activated via various triggers, ensuring compatibility with devices like Mag Locks and Electric Strikes. The unit supports both Fail-Safe and Fail-Secure modes, while the FACP Interface allows for emergency egress and alarm monitoring. Elevate your security setup with the Altronix EFLOW6NA8V – order yours today!
Principales caractéristiques
Renseignements généraux
Nom:Altronix EFLOW6NA8V Power Supply with ACM8
Category:Altronix, Batteries & Power Supplies, Power Supplies & Boards, Access Power Controllers
UPC Code:
Country of Origin:. Country of origin is subject to change.
Spécifications
ADI Numéro du produit AX-EFLOW68V Code fabricant EFLOW6NA8V Fabricant Altronix Corporation Gamme eFlowNAD Genre du connecteur Access Control Marque Altronix Modèle de produit EFLOW6NA8V Nom de produit Access Power Controller With Power Supply/Charger, 8 Fused Relay Outputs, 12/24VDC, 6A, Aux Output, FAI, 220VAC, BC400 Enclosure Type de produit Access Power Controller
Nombre de porte(s) 8 Tension de sortie 12V DC, 24V DC
NDAA Compliant Yes
Température de fonctionnement 32-120°F Temperature de stockage (T-T) -4-158°F
Hauteur 16" Largeur 12" Poids 8.6lb Profondeur 4.5"
Tension d'entrée 220V AC
Garantie Limitée Lifetime
Caractéristiques AC fail supervision (form "C" contacts), Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1A 28VDC not evaluated by UL), Automatic switch over to stand-by battery when AC fails. Transfer to stand-by battery power is instantaneous with no interruption, Battery fail & presence supervision (form "C" contacts)., Built-in charger for sealed lead acid or gel type batteries, Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs, Low power shutdown. Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge., Normally open (NO) or normally closed (NC) dry contact input, Polarity reversal input from FACP signaling circuit, Zero voltage drop when unit switches over to battery backup (AC failure condition) Certification environnementale RoHS Intérieur/extérieur Indoor