Altronix
Altronix EFLOW104NA8V Power Supply with ACM8
EFLOW104NA8V | AX-EFLOW18V
Veuillez vous connecter pour voir les tarifs, consulter la disponibilité des produits et ajouter des articles à votre panier.
Aperçu
Spécifications
Documents
Aperçu
Introducing the Altronix EFLOW104NA8V, a versatile power supply designed to efficiently distribute and manage power for access control systems and accessories. This unit transforms a 220V AC input into eight independently controlled 24V DC outputs, each protected by fuses and capable of delivering a total of 10A continuous current. Ideal for various access control devices such as mag locks and electric strikes, it supports both fail-safe and fail-secure modes. The FACP interface allows for emergency egress and alarm monitoring, ensuring safety and reliability. Upgrade your security system with the Altronix EFLOW104NA8V today!
Principales caractéristiques
Renseignements généraux
Nom:Altronix EFLOW104NA8V Power Supply with ACM8
Category:Altronix, Batteries & Power Supplies, Power Supplies & Boards, Access Power Controllers
UPC Code:
Country of Origin:. Country of origin is subject to change.
Spécifications
ADI Numéro du produit AX-EFLOW18V Code fabricant EFLOW104NA8V Fabricant Altronix Corporation Gamme EFLOW Genre du connecteur Access Control Marque Altronix Modèle de produit EFLOW104NA8V Nom de produit Access Power Controller With Power Supply/Charger, 8 Fused Relay Outputs, 24VDC at 10A, Aux Output, FAI, 220VAC, BC400 Enclosure Type de produit Access Power Controller
Nombre de porte(s) 8 Tension de sortie 24V DC
NDAA Compliant Yes
Température de fonctionnement 32-120°F Temperature de stockage (T-T) -4-158°F
Hauteur 16" Largeur 12.25" Poids 8.9lb Profondeur 4.5"
Tension d'entrée 220V AC
Garantie Limitée Lifetime
Caractéristiques AC fail supervision (form "C" contacts), Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1A 28VDC not evaluated by UL), Automatic switch over to stand-by battery when AC fails. Transfer to stand-by battery power is instantaneous with no interruption, Battery fail & presence supervision (form "C" contacts), Built-in charger for sealed lead acid or gel type batteries., Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs, Low power shutdown. Shuts down DC output terminals if battery voltage drops below 70-75% (depending on the power supply). Prevents deep battery discharge, Normally open (NO) or normally closed (NC) dry contact input, Polarity reversal input from FACP signaling circuit., Zero voltage drop when unit switches over to battery backup (AC failure condition) Certification environnementale RoHS Intérieur/extérieur Indoor
