adi-insite-ca
ADI a Resideo company
menu
Image of AX-1012ACM22

Altronix AL1012ACM220 Access Power Controller with Power Supply Charger, Fused Relay Outputs, 12VDC at 10A, FAI, 220VAC, BC400 Enclosure

AL1012ACM220|AX-1012ACM22

Altronix AL1012ACM220 Access Power Controller with Power Supply Charger, Fused Relay Outputs, 12VDC at 10A, FAI, 220VAC, BC400 Enclosure

AL1012ACM220|AX-1012ACM22

Se connecter prix revendeur

Devenir client ADI
Altronix

Altronix AL1012ACM220 Access Power Controller with Power Supply Charger, Fused Relay Outputs, 12VDC at 10A, FAI, 220VAC, BC400 Enclosure

AL1012ACM220 | AX-1012ACM22

Veuillez vous connecter pour voir les tarifs, consulter la disponibilité des produits et ajouter des articles à votre panier.

Aperçu
Spécifications
Documents

Aperçu

Introducing the Altronix AL1012ACM220 Access Power Controller, a robust solution designed to convert 220VAC input into eight independently controlled 12VDC outputs, delivering a total of 10A continuous supply current. This versatile unit supports various access control devices, including mag locks and electric strikes, operating in both fail-safe and fail-secure modes. With features like selectable fire alarm disconnect, short circuit protection, and a built-in battery charger for seamless power backup, it ensures reliable performance. Ideal for security applications, this power controller is your go-to choice for efficient access management. Don't miss out—secure your access control system today!

Principales caractéristiques

  • Eight (8) independently controlled Outputs.
  • Output options: a) Eight (8) Fail-Safe and/or Fail-Secure power outputs; b) Eight (8) formin.C" 5A rated relay outputs; c) Any combination of the above.
  • Eight (8) auxiliary power outputs (unswitched).
  • Output fuses are rated at 3.5A.
  • Filtered and electronically regulated outputs.
  • Supervision: - AC Fail - Battery Fail and Battery Presence.
  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
  • Alarm output relay indicates that FACP input is triggered.
  • Fire Alarm disconnect input options: a) Normally open (NO) or normally closed (NC) dry contact input b) Polarity reversal input from FACP signaling circuit.
  • Fire Alarm disconnect input options:a) Normally open (NO) or normally closed (NC) dry contact inputb) Polarity reversal input from FACP signaling circuit.
  • Renseignements généraux

    Nom:Altronix AL1012ACM220 Access Power Controller with Power Supply Charger, Fused Relay Outputs, 12VDC at 10A, FAI, 220VAC, BC400 Enclosure
    Category:Altronix, Batteries & Power Supplies, Power Supplies & Boards, Access Power Controllers
    UPC Code:782239943821
    Country of Origin:United States. Country of origin is subject to change.

    Spécifications

    Documents et ressources sur les produits